BC Step Code · live calculator

Spec the window.
See if it meets your target.

Dial in glass type, frame system, cavity fill, and spacer. The four performance metrics (U-value, SHGC, VT, and air leakage) recalculate in real time and check against BC Step Code 3 / 4 / 5 hard targets. SHGC is shown as an informational design input; the Step Code doesn't prescribe a strict SHGC range. Recommended Catalyst products at the bottom update with the spec.

Climate zones 4–7 Targets verified May 2026 Source energystepcode.ca
UBC Museum of Anthropology. RAICO Therm+ S-I curved steel façade seen from inside the cafeteria.
UBC Museum of Anthropology · RAICO Therm+ S-I curved steel façade, glazed by Catalyst

Configuration

Build the spec. The performance side updates as you go.

Performance

Compared against the BC Step Code target you selected.

Targeting: BC Step Code 3
U-value
1.42W/m²K
Target: ≤ 1.40 · Just below
SHGC · solar heat gain (design input)
0.40
Suggested: 0.35 – 0.45 · In suggested range
VT · visible transmittance
0.70
Target: ≥ 0.40 · Exceeds
Air leakage
0.20L/s·m²
Target: ≤ 0.20 · A440 commercial

These are modelled figures for scoping, not test data. Before anything goes into a permit submission, confirm the numbers against the manufacturer's NFRC report and your energy advisor.

Meets all Step Code 3 targets

Suggested Catalyst products

1
Cortizo COR Vision Plus Sliding
U 0.90 SHGC 0.30 VT 0.50 Air 0.08
Meets all
Get a real quote with this spec

Targets verified May 2026 · source energystepcode.ca

How the calculator works

Hard targets vs. design inputs: what the BC Step Code actually says.

Hard targets

U-value, VT, Air leakage

These three are checked as pass/fail. Step 3 / 4 / 5 set increasingly stringent maximum U-values and air-leakage limits, and a minimum VT for daylighting. Colder climate zones tighten the U-target further (zone 7 subtracts 0.20 from the baseline).

Design input

SHGC: informational only

The Step Code does not prescribe a strict SHGC range. SHGC feeds the energy compliance model (HOT2000, NECB), not pass/fail. Lower SHGC favours cooling-dominant facades; moderate SHGC helps with passive winter heating. We surface it as a suggested range, not a hard target.